Commit Graph

4905 Commits

Author SHA1 Message Date
jbrazio
45dc8a51f3 Added readme file for bqh2 and disabled the SLOWDOWN config flag 2016-03-06 05:51:57 -08:00
Scott Lahteine
6a21180bd4 Implemented BQ ZUM Mega 3D board layout as an override to RAMPS 1.3 2016-03-06 05:51:57 -08:00
jbrazio
b18816fcbf Fine tuned XYJERK.
Disallowed the Z_PROBE_OFFSET_RANGE_MAX to be greater than zero.
2016-03-06 05:51:57 -08:00
jbrazio
be83036212 Applying suggestions by @thinkyhead at MarlinFirmware/Marlin#3049.
- Remove the forced activation of SDSUPPORT, I guess people may use the ZUM
3D board and not the LCD module.
 - Fixed the tab issue within boards.h file.
2016-03-06 05:51:56 -08:00
jbrazio
b82d91eca6 Added configuration example for the BQ Hephestos 2 3D printer.
Added support for BQ ZUM Mega 3D board and stock Hephestos 2 thermistor.
2016-03-06 05:51:56 -08:00
Scott Lahteine
45bcc43e48 Don't override SOURCE_CODE_URL in Default_Version.h
- Defining `SOURCE_CODE_URL` in `Default_Version.h` overrides it
elsewhere. So don’t define it there.
- Also fix up `language.h` so no `#undef` will be needed.
2016-03-06 05:51:56 -08:00
Scott Lahteine
ef68c1910c Check that the temperature is close to target 2016-03-06 05:51:56 -08:00
Scott Lahteine
ea9fd1200b Fix M109 so it won't wait for cooling
Addressing issue #2767
2016-03-06 05:51:56 -08:00
Scott Lahteine
e4945b30d2 sbi and cbi are deprecated 2016-03-06 05:51:55 -08:00
Scott Lahteine
ff13070b59 Use _BV macros, patch up others 2016-03-06 05:51:55 -08:00
Scott Lahteine
209f5f21e0 Use macros where possible
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
2016-03-06 05:51:55 -08:00
Scott Lahteine
c8f76bb8aa Create BITSET/BITCLR macros 2016-03-06 05:51:55 -08:00
Scott Lahteine
adc25db8c4 Merge pull request #3005 from thinkyhead/rcbugfix_eeprom
Fix layout descr. in configuration_store.cpp
2016-03-06 00:31:44 -08:00
Scott Lahteine
e7cf85b922 Merge pull request #3013 from thinkyhead/esenapaj-patch-1
Enhanced #3010 - formal Mesh/Manual dependency
2016-03-06 00:30:02 -08:00
Scott Lahteine
6e64895c30 Merge pull request #3001 from AlwaysTinkering/RCBugFix
Rc bug fix - Fix for issue #2931
2016-03-06 00:20:29 -08:00
Scott Lahteine
34b8b9f0f5 Merge pull request #2995 from thinkyhead/rcbugfix_corexy_corexz
Add CORE support to st_get_position_mm (and elsewhere)
2016-03-06 00:17:03 -08:00
Scott Lahteine
1e20949afb Merge pull request #3092 from thinkyhead/rc_2860_printrbot_lcd
Fix Printrboard with LCD (redo)
2016-03-06 00:14:29 -08:00
Scott Lahteine
f5972c4d2c Merge pull request #2994 from AnHardt/Inerrup-save-serial
Interrupt safe serial --- Guard against non-atomic variable changes from interrupt routines
2016-03-05 22:25:12 -08:00
Scott Lahteine
3a3d358df9 Fix Printrboard with LCD (redo)
Based on #2860 - rebased for RCBugFix
2016-03-05 22:13:00 -08:00
Scott Lahteine
eb85342fd9 Merge pull request #2989 from AnHardt/fix2661
Pre home display - Stepper release
2016-03-05 21:30:17 -08:00
Scott Lahteine
14f3ca1b2e Merge pull request #2978 from thinkyhead/tool_offset_abl_rcbugfix
Apply bed leveling matrix when switching extruders
2016-03-05 21:23:25 -08:00
Scott Lahteine
91fcdc2b99 Merge pull request #3090 from thinkyhead/rc_spelling
Various minor spelling corrections
2016-03-05 20:50:34 -08:00
Scott Lahteine
772460a7b8 Various minor spelling corrections
Redo of #2939 rebased against RCBugFix
2016-03-05 20:41:15 -08:00
Scott Lahteine
aa0b0483f4 Merge pull request #3089 from thinkyhead/rc_apply_2924
Correct raise_z_for_servo for Z offsets below the nozzle
2016-03-05 20:23:14 -08:00
lrpirlet
0fb507a75d correct raise_z_for_servo 2016-03-05 20:19:53 -08:00
Scott Lahteine
04a0d45c22 Merge pull request #2821 from MarlinFirmware/ReinitializeDisplay
Fix status LEDs update when reinitializing the display
2016-03-05 15:31:49 -08:00
Blue-Marlin
b4e5e0f11d Add Watchdog reset in kill()
Add watchdog reset in the kill loop to simplify recovering.
2016-03-04 00:35:18 +01:00
Scott Lahteine
547d35a921 Merge pull request #3067 from Blue-Marlin/ALARM_PIN
Remove unused ALARM_PIN
2016-03-02 20:20:26 -08:00
Scott Lahteine
79778d46d9 Merge pull request #3066 from Blue-Marlin/Fix-disable_all_heaters()
Fix disable_all_heaters() for MAX6675
2016-03-02 17:35:08 -08:00
Blue-Marlin
a68228bf55 Remove unused ALARM_PIN
Remove unused ALARM_PIN from all the Configuration.h's
2016-03-02 14:29:49 +01:00
Scott Lahteine
9eb4aceee4 Merge pull request #2986 from thinkyhead/enable_watchdog
Enable USE_WATCHDOG by default
2016-03-02 05:29:42 -08:00
Blue-Marlin
0631541166 Fix disable_all_heaters() for MAX6675 2016-03-02 14:17:23 +01:00
Scott Lahteine
222d13d5ed Merge pull request #3051 from thinkyhead/rcbugfix_dual_axis_offset
Code cleanup in gcode_T
2016-03-02 03:45:40 -08:00
Scott Lahteine
186629aee8 Merge pull request #3057 from jbrazio/3034-z_raise_after_probing_fix
Fix Z_RAISE_AFTER_PROBING for non DELTA printers
2016-03-02 03:14:27 -08:00
Scott Lahteine
a42fb35c56 Merge pull request #3050 from Blue-Marlin/fix-1166
Temporary workaround for stack overflow
2016-03-01 11:33:19 -08:00
jbrazio
67e15aac3d As pointed out by @Blue-Marlin the previous code would raise the Z axis
twice for a servo based probe.
2016-03-01 00:22:48 +00:00
jbrazio
17cc2a9663 Z_RAISE_AFTER_PROBING value was being ignored by Marlin because
raise_z_after_probing() was only called if the printer type was set to a
DELTA or if the printer had a docking sled for the probe.
2016-02-29 15:48:26 +00:00
Scott Lahteine
252f4a75cd Merge pull request #3043 from oxivanisher/RCBugFix
Example configuration for Kossel XL
2016-02-28 23:57:13 -08:00
Scott Lahteine
fd1243c184 Merge pull request #3052 from thinkyhead/rc_fix_m145_eeprom_output
Fix "M145" output in M503 report
2016-02-28 23:43:08 -08:00
Scott Lahteine
0bc648353f Merge pull request #3031 from tnw513/RCBugFix
Fix board type for Hephestos: RAMPS 1.4
2016-02-28 23:23:01 -08:00
AnHardt
f27c2b6b4b Reimplement #2892
Include #2892 to fix the isHeating symbol in the extruder graphics
2016-02-28 23:20:30 +01:00
AnHardt
615bec2329 Activate warning about possible reduced accuracy by default
Renamed `WARN_REDUCED_ACCURACY` to `DISABLE_REDUCED_ACCURACY_WARNING`

Changed the condition for blinking from
```
#if ENABLED(WARN_REDUCED_ACCURACY)
```
to
```
#if DISABLED(DISABLE_REDUCED_ACCURACY_WARNING)
```
2016-02-28 23:20:21 +01:00
AnHardt
1c889cd303 Refresh previous_cmd_ms during run_z_probe()
Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238)
2016-02-28 23:20:12 +01:00
AnHardt
4b02f33e69 Distribute config-changes to the other configurations 2016-02-28 23:20:04 +01:00
AnHardt
be24fdacea The same changes to the axis-letters now for the char-displays
Exactly the same - copy/paste.
2016-02-28 23:19:54 +01:00
AnHardt
5b0f659355 Changes for graphics displays
Replaced displaying "---" instead of the value of a coordinate when
unhomed or with reduced precision
with blinking the coordinate-prefix-character ('X','Y','Z').
For "unhomed" a '?' is shown every second second - until that axis is
homed. The value displayed is, as before the "---" where displayed, the
relative to the reset position coordinate value.
When the axis stepper was disabled, now we can display a hint on that,
by showing a blinking ' ' instead of the axis letter, when
WARN_REDUCED_ACCURACY is defined.

I suppose the code itself is here the better documentation.

A '+/-' character is in non of our charsets so i decided for a '?' for
now to reduce the work.
There is no additional space on the displays one could use to display
the information, so replacing something is the only option. As the axis
letters are totally redundant with their positions on the display they
contain the least information.
So my decision was to overwrite them.
2016-02-28 23:19:32 +01:00
AnHardt
32ae9f9ab7 Fix stepper shutdown during waiting for temperatures
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.

The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.

# Conflicts:
#	Marlin/Configuration_adv.h
2016-02-28 16:58:50 +01:00
AnHardt
b6e69e71ce Make stepper shutdown after inactivity dependent
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E

And make exemplaric Configuration.
Names can be discussed.

This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
2016-02-28 16:58:42 +01:00
AnHardt
051325ccd7 Introduce axis_homed
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".

# Conflicts:
#	Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
2016-02-28 16:58:28 +01:00
AnHardt
e736779d7e blink for char-lcds
Implement and test blinking for char-lcds

# Conflicts:
#	Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
2016-02-28 16:58:19 +01:00