113 lines
		
	
	
		
			4.0 KiB
		
	
	
	
		
			C++
		
	
	
	
	
	
			
		
		
	
	
			113 lines
		
	
	
		
			4.0 KiB
		
	
	
	
		
			C++
		
	
	
	
	
	
/**
 | 
						|
 * Marlin 3D Printer Firmware
 | 
						|
 * Copyright (c) 2020 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
 | 
						|
 *
 | 
						|
 * Based on Sprinter and grbl.
 | 
						|
 * Copyright (c) 2011 Camiel Gubbels / Erik van der Zalm
 | 
						|
 *
 | 
						|
 * This program is free software: you can redistribute it and/or modify
 | 
						|
 * it under the terms of the GNU General Public License as published by
 | 
						|
 * the Free Software Foundation, either version 3 of the License, or
 | 
						|
 * (at your option) any later version.
 | 
						|
 *
 | 
						|
 * This program is distributed in the hope that it will be useful,
 | 
						|
 * but WITHOUT ANY WARRANTY; without even the implied warranty of
 | 
						|
 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
 | 
						|
 * GNU General Public License for more details.
 | 
						|
 *
 | 
						|
 * You should have received a copy of the GNU General Public License
 | 
						|
 * along with this program.  If not, see <http://www.gnu.org/licenses/>.
 | 
						|
 *
 | 
						|
 */
 | 
						|
#pragma once
 | 
						|
 | 
						|
#include "../inc/MarlinConfig.h"
 | 
						|
 | 
						|
enum TempSensorID : uint8_t {
 | 
						|
  TSI_PROBE,
 | 
						|
  TSI_BED,
 | 
						|
  #if ENABLED(USE_TEMP_EXT_COMPENSATION)
 | 
						|
    TSI_EXT,
 | 
						|
  #endif
 | 
						|
  TSI_COUNT
 | 
						|
};
 | 
						|
 | 
						|
typedef struct {
 | 
						|
  uint8_t measurements; // Max. number of measurements to be stored (35 - 80°C)
 | 
						|
  float   temp_res,     // Resolution in °C between measurements
 | 
						|
          start_temp,   // Base measurement; z-offset == 0
 | 
						|
          end_temp;
 | 
						|
} temp_calib_t;
 | 
						|
 | 
						|
/**
 | 
						|
 * Probe temperature compensation implementation.
 | 
						|
 * Z-probes like the P.I.N.D.A V2 allow for compensation of
 | 
						|
 * measurement errors/shifts due to changed temperature.
 | 
						|
 */
 | 
						|
 | 
						|
static constexpr temp_calib_t cali_info_init[TSI_COUNT] = {
 | 
						|
    {  10,  5,  30,  30 + 10 *  5 },       // Probe
 | 
						|
    {  10,  5,  60,  60 + 10 *  5 },       // Bed
 | 
						|
  #if ENABLED(USE_TEMP_EXT_COMPENSATION)
 | 
						|
    {  20,  5, 180, 180 +  5 * 20 }        // Extruder
 | 
						|
  #endif
 | 
						|
};
 | 
						|
 | 
						|
class ProbeTempComp {
 | 
						|
  public:
 | 
						|
 | 
						|
    static const temp_calib_t cali_info[TSI_COUNT];
 | 
						|
 | 
						|
    // Where to park nozzle to wait for probe cooldown
 | 
						|
    static constexpr xyz_pos_t park_point = PTC_PARK_POS;
 | 
						|
 | 
						|
    // XY coordinates of nozzle for probing the bed
 | 
						|
    static constexpr xy_pos_t measure_point    = PTC_PROBE_POS;     // Coordinates to probe
 | 
						|
                            //measure_point    = { 12.0f, 7.3f };   // Coordinates for the MK52 magnetic heatbed
 | 
						|
 | 
						|
    static constexpr int  probe_calib_bed_temp = BED_MAX_TARGET,  // Bed temperature while calibrating probe
 | 
						|
                          bed_calib_probe_temp = 30;                // Probe temperature while calibrating bed
 | 
						|
 | 
						|
    static int16_t *sensor_z_offsets[TSI_COUNT],
 | 
						|
                   z_offsets_probe[cali_info_init[TSI_PROBE].measurements], // (µm)
 | 
						|
                   z_offsets_bed[cali_info_init[TSI_BED].measurements];     // (µm)
 | 
						|
 | 
						|
    #if ENABLED(USE_TEMP_EXT_COMPENSATION)
 | 
						|
      static int16_t z_offsets_ext[cali_info_init[TSI_EXT].measurements];   // (µm)
 | 
						|
    #endif
 | 
						|
 | 
						|
    static inline void reset_index() { calib_idx = 0; };
 | 
						|
    static inline uint8_t get_index() { return calib_idx; }
 | 
						|
    static void clear_offsets(const TempSensorID tsi);
 | 
						|
    static inline void clear_all_offsets() {
 | 
						|
      clear_offsets(TSI_BED);
 | 
						|
      clear_offsets(TSI_PROBE);
 | 
						|
      TERN_(USE_TEMP_EXT_COMPENSATION, clear_offsets(TSI_EXT));
 | 
						|
    }
 | 
						|
    static bool set_offset(const TempSensorID tsi, const uint8_t idx, const int16_t offset);
 | 
						|
    static void print_offsets();
 | 
						|
    static void prepare_new_calibration(const float &init_meas_z);
 | 
						|
    static void push_back_new_measurement(const TempSensorID tsi, const float &meas_z);
 | 
						|
    static bool finish_calibration(const TempSensorID tsi);
 | 
						|
    static void compensate_measurement(const TempSensorID tsi, const float &temp, float &meas_z);
 | 
						|
 | 
						|
  private:
 | 
						|
    static uint8_t calib_idx;
 | 
						|
 | 
						|
    /**
 | 
						|
     * Base value. Temperature compensation values will be deltas
 | 
						|
     * to this value, set at first probe.
 | 
						|
     */
 | 
						|
    static float init_measurement;
 | 
						|
 | 
						|
    static float get_offset_for_temperature(const TempSensorID tsi, const float &temp);
 | 
						|
 | 
						|
    /**
 | 
						|
     * Fit a linear function in measured temperature offsets
 | 
						|
     * to allow generating values of higher temperatures.
 | 
						|
     */
 | 
						|
    static bool linear_regression(const TempSensorID tsi, float &k, float &d);
 | 
						|
};
 | 
						|
 | 
						|
extern ProbeTempComp temp_comp;
 |