@ -852,25 +852,34 @@ float junction_deviation = 0.1;
|
|
|
|
|
block->nominal_rate = ceil(block->step_event_count * inverse_second); // (step/sec) Always > 0
|
|
|
|
|
|
|
|
|
|
#if ENABLED(FILAMENT_WIDTH_SENSOR)
|
|
|
|
|
static float filwidth_e_count = 0, filwidth_delay_dist = 0;
|
|
|
|
|
|
|
|
|
|
//FMM update ring buffer used for delay with filament measurements
|
|
|
|
|
if (extruder == FILAMENT_SENSOR_EXTRUDER_NUM && delay_index2 > -1) { //only for extruder with filament sensor and if ring buffer is initialized
|
|
|
|
|
if (extruder == FILAMENT_SENSOR_EXTRUDER_NUM && filwidth_delay_index2 >= 0) { //only for extruder with filament sensor and if ring buffer is initialized
|
|
|
|
|
|
|
|
|
|
const int MMD = MAX_MEASUREMENT_DELAY + 1, MMD10 = MMD * 10;
|
|
|
|
|
const int MMD_CM = MAX_MEASUREMENT_DELAY + 1, MMD_MM = MMD_CM * 10;
|
|
|
|
|
|
|
|
|
|
delay_dist += delta_mm[E_AXIS]; // increment counter with next move in e axis
|
|
|
|
|
while (delay_dist >= MMD10) delay_dist -= MMD10; // loop around the buffer
|
|
|
|
|
while (delay_dist < 0) delay_dist += MMD10;
|
|
|
|
|
// increment counters with next move in e axis
|
|
|
|
|
filwidth_e_count += delta_mm[E_AXIS];
|
|
|
|
|
filwidth_delay_dist += delta_mm[E_AXIS];
|
|
|
|
|
|
|
|
|
|
delay_index1 = delay_dist / 10.0; // calculate index
|
|
|
|
|
delay_index1 = constrain(delay_index1, 0, MAX_MEASUREMENT_DELAY); // (already constrained above)
|
|
|
|
|
// Only get new measurements on forward E movement
|
|
|
|
|
if (filwidth_e_count > 0.0001) {
|
|
|
|
|
|
|
|
|
|
if (delay_index1 != delay_index2) { // moved index
|
|
|
|
|
// Loop the delay distance counter (modulus by the mm length)
|
|
|
|
|
while (filwidth_delay_dist >= MMD_MM) filwidth_delay_dist -= MMD_MM;
|
|
|
|
|
|
|
|
|
|
// Convert into an index into the measurement array
|
|
|
|
|
filwidth_delay_index1 = (int)(filwidth_delay_dist / 10.0 + 0.0001);
|
|
|
|
|
|
|
|
|
|
// If the index has changed (must have gone forward)...
|
|
|
|
|
if (filwidth_delay_index1 != filwidth_delay_index2) {
|
|
|
|
|
filwidth_e_count = 0; // Reset the E movement counter
|
|
|
|
|
int8_t meas_sample = widthFil_to_size_ratio() - 100; // Subtract 100 to reduce magnitude - to store in a signed char
|
|
|
|
|
while (delay_index1 != delay_index2) {
|
|
|
|
|
// Increment and loop around buffer
|
|
|
|
|
if (++delay_index2 >= MMD) delay_index2 -= MMD;
|
|
|
|
|
delay_index2 = constrain(delay_index2, 0, MAX_MEASUREMENT_DELAY);
|
|
|
|
|
measurement_delay[delay_index2] = meas_sample;
|
|
|
|
|
do {
|
|
|
|
|
filwidth_delay_index2 = (filwidth_delay_index2 + 1) % MMD_CM; // The next unused slot
|
|
|
|
|
measurement_delay[filwidth_delay_index2] = meas_sample; // Store the measurement
|
|
|
|
|
} while (filwidth_delay_index1 != filwidth_delay_index2); // More slots to fill?
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|