Set MAX_OVERSHOOT_PID_AUTOTUNE to 30 (#15257)

2.0.x
Robby Candra 5 years ago committed by Scott Lahteine
parent f98999ca20
commit c3f09e2b1b

@ -500,7 +500,7 @@ volatile bool Temperature::temp_meas_ready = false;
// Did the temperature overshoot very far?
#ifndef MAX_OVERSHOOT_PID_AUTOTUNE
#define MAX_OVERSHOOT_PID_AUTOTUNE 20
#define MAX_OVERSHOOT_PID_AUTOTUNE 30
#endif
if (current_temp > target + MAX_OVERSHOOT_PID_AUTOTUNE) {
SERIAL_ECHOLNPGM(MSG_PID_TEMP_TOO_HIGH);