@ -215,7 +215,7 @@ Here are some standard links for getting your machine calibrated:
|
|
|
|
|
// If your configuration is significantly different than this and you don't understand the issues involved, you probably
|
|
|
|
|
// shouldn't use bed PID until someone else verifies your hardware works.
|
|
|
|
|
// If this is enabled, find your own PID constants below.
|
|
|
|
|
#define PIDTEMPBED
|
|
|
|
|
//#define PIDTEMPBED
|
|
|
|
|
//
|
|
|
|
|
//#define BED_LIMIT_SWITCHING
|
|
|
|
|
|
|
|
|
@ -226,10 +226,17 @@ Here are some standard links for getting your machine calibrated:
|
|
|
|
|
#define MAX_BED_POWER 255 // limits duty cycle to bed; 255=full current
|
|
|
|
|
|
|
|
|
|
#ifdef PIDTEMPBED
|
|
|
|
|
// Felix Foil Heater
|
|
|
|
|
#define DEFAULT_bedKp 103.37
|
|
|
|
|
#define DEFAULT_bedKi 2.79
|
|
|
|
|
#define DEFAULT_bedKd 956.94
|
|
|
|
|
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
|
|
|
|
//from FOPDT model - kp=.39 Tp=405 Tdead=66, Tc set to 79.2, aggressive factor of .15 (vs .1, 1, 10)
|
|
|
|
|
#define DEFAULT_bedKp 10.00
|
|
|
|
|
#define DEFAULT_bedKi .023
|
|
|
|
|
#define DEFAULT_bedKd 305.4
|
|
|
|
|
|
|
|
|
|
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
|
|
|
|
//from pidautotune
|
|
|
|
|
// #define DEFAULT_bedKp 97.1
|
|
|
|
|
// #define DEFAULT_bedKi 1.41
|
|
|
|
|
// #define DEFAULT_bedKd 1675.16
|
|
|
|
|
|
|
|
|
|
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
|
|
|
|
|
#endif // PIDTEMPBED
|
|
|
|
@ -273,15 +280,15 @@ your extruder heater takes 2 minutes to hit the target on heating.
|
|
|
|
|
// uncomment the 2 defines below:
|
|
|
|
|
|
|
|
|
|
// Parameters for all extruder heaters
|
|
|
|
|
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 60 //in seconds
|
|
|
|
|
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 5 // in degree Celsius
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 //in seconds
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
|
|
|
|
|
|
|
|
|
// If you want to enable this feature for your bed heater,
|
|
|
|
|
// uncomment the 2 defines below:
|
|
|
|
|
|
|
|
|
|
// Parameters for the bed heater
|
|
|
|
|
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 30 //in seconds
|
|
|
|
|
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 5// in degree Celsius
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 //in seconds
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
//===========================================================================
|
|
|
|
|