Sanity check PIDTEMPBED plus BED_LIMIT_SWITCHING
This commit is contained in:
		
							parent
							
								
									8cb04816b5
								
							
						
					
					
						commit
						5955a3063f
					
				| @ -131,10 +131,16 @@ | ||||
|   #error You must enable either DISPLAY_CHARSET_HD44780_JAPAN or DISPLAY_CHARSET_HD44780_WESTERN  or DISPLAY_CHARSET_HD44780_CYRILLIC for your LCD controller. | ||||
| #endif | ||||
| 
 | ||||
| /**
 | ||||
|  * Bed Heating Options - PID vs Limit Switching | ||||
|  */ | ||||
| #if ENABLED(PIDTEMPBED) && ENABLED(BED_LIMIT_SWITCHING) | ||||
|   #error To use BED_LIMIT_SWITCHING you must disable PIDTEMPBED. | ||||
| #endif | ||||
| 
 | ||||
| /**
 | ||||
|  * Mesh Bed Leveling | ||||
|  */ | ||||
| 
 | ||||
| #if ENABLED(MESH_BED_LEVELING) | ||||
|   #if ENABLED(DELTA) | ||||
|     #error MESH_BED_LEVELING does not yet support DELTA printers. | ||||
|  | ||||
| @ -286,7 +286,7 @@ | ||||
| // If this is enabled, find your own PID constants below.
 | ||||
| #define PIDTEMPBED | ||||
| 
 | ||||
| #define BED_LIMIT_SWITCHING | ||||
| //#define BED_LIMIT_SWITCHING
 | ||||
| 
 | ||||
| // This sets the max power delivered to the bed, and replaces the HEATER_BED_DUTY_CYCLE_DIVIDER option.
 | ||||
| // all forms of bed control obey this (PID, bang-bang, bang-bang with hysteresis)
 | ||||
|  | ||||
| @ -745,7 +745,7 @@ void manage_heater() { | ||||
|         soft_pwm_bed = 0; | ||||
|         WRITE_HEATER_BED(LOW); | ||||
|       } | ||||
|     #else // BED_LIMIT_SWITCHING
 | ||||
|     #else // !PIDTEMPBED && !BED_LIMIT_SWITCHING
 | ||||
|       // Check if temperature is within the correct range
 | ||||
|       if (current_temperature_bed > BED_MINTEMP && current_temperature_bed < BED_MAXTEMP) { | ||||
|         soft_pwm_bed = current_temperature_bed < target_temperature_bed ? MAX_BED_POWER >> 1 : 0; | ||||
|  | ||||
		Loading…
	
	
			
			x
			
			
		
	
		Reference in New Issue
	
	Block a user