Due to the fix for #1248, X and Y probe offsets must not be floats.

The compiler does not support comparing float values: "error: floating constant in preprocessor expression"
The loss in X/Y precision shouldn't matter for Z probes, as most microswitches or inductive sensors are larger than 1mm square anyway.
2.0.x
Lane Roberts 10 years ago committed by Alexander Hirzel
parent b32be2dc64
commit 1f520a5a8c

@ -392,6 +392,7 @@ const bool Z_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of
// these are the offsets to the probe relative to the extruder tip (Hotend - Probe)
// X and Y offsets must be integers
#define X_PROBE_OFFSET_FROM_EXTRUDER -25
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35