Fix bilinear levelling z offset
Since run_probe was altered to return the probe Z position rather than the nozzle Z position bilinear levelling has been broken because the Z-offset has been applied twice - once in the run_probe function, and then again in the G29 code for bilinear levelling.
This commit is contained in:
		
							parent
							
								
									44a849bdce
								
							
						
					
					
						commit
						0a2b4f3486
					
				| @ -4300,7 +4300,7 @@ inline void gcode_G28() { | ||||
| 
 | ||||
|         #elif ENABLED(AUTO_BED_LEVELING_BILINEAR) | ||||
| 
 | ||||
|           bed_level_grid[xCount][yCount] = measured_z + zoffset; | ||||
|           bed_level_grid[xCount][yCount] = measured_z; | ||||
| 
 | ||||
|         #elif ENABLED(AUTO_BED_LEVELING_3POINT) | ||||
| 
 | ||||
| @ -4472,7 +4472,7 @@ inline void gcode_G28() { | ||||
| 
 | ||||
|             #elif ENABLED(AUTO_BED_LEVELING_BILINEAR) | ||||
| 
 | ||||
|               bed_level_grid[xCount][yCount] = measured_z + zoffset; | ||||
|               bed_level_grid[xCount][yCount] = measured_z; | ||||
| 
 | ||||
|             #endif | ||||
| 
 | ||||
|  | ||||