@ -70,7 +70,7 @@ Here are some standard links for getting your machine calibrated:
// #define MACHINE_UUID "00000000-0000-0000-0000-000000000000"
// This defines the number of extruders
#define EXTRUDERS 2
#define EXTRUDERS 1
//// The following define selects which power supply you have. Please choose the one that matches your setup
// 1 = ATX
@ -205,7 +205,7 @@ Here are some standard links for getting your machine calibrated:
// If your configuration is significantly different than this and you don't understand the issues involved, you probably
// shouldn't use bed PID until someone else verifies your hardware works.
// If this is enabled, find your own PID constants below.
//#define PIDTEMPBED
#define PIDTEMPBED
//
//#define BED_LIMIT_SWITCHING
@ -216,17 +216,10 @@ Here are some standard links for getting your machine calibrated:
#define MAX_BED_POWER 255 // limits duty cycle to bed; 255=full current
#ifdef PIDTEMPBED
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
//from FOPDT model - kp=.39 Tp=405 Tdead=66, Tc set to 79.2, aggressive factor of .15 (vs .1, 1, 10)
#define DEFAULT_bedKp 10.00
#define DEFAULT_bedKi .023
#define DEFAULT_bedKd 305.4
//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
//from pidautotune
// #define DEFAULT_bedKp 97.1
// #define DEFAULT_bedKi 1.41
// #define DEFAULT_bedKd 1675.16
// Felix Foil Heater
#define DEFAULT_bedKp 103.37
#define DEFAULT_bedKi 2.79
#define DEFAULT_bedKd 956.94
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
#endif // PIDTEMPBED
@ -270,15 +263,15 @@ your extruder heater takes 2 minutes to hit the target on heating.
// uncomment the 2 defines below:
// Parameters for all extruder heaters
//#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 //in seconds
//#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 60 //in seconds
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 5 // in degree Celsius
// If you want to enable this feature for your bed heater,
// uncomment the 2 defines below:
// Parameters for the bed heater
//#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 //in seconds
//#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 30 //in seconds
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 5// in degree Celsius
//===========================================================================